HP Netserver LP 2000r User Guide

Appendix A Specifications
120
Table A-2. Environmental Requirements
Parameter Conditions
Temperature
Operating
5
° to 35° C (41° to 95° F)
Non-operating -40° to +65° C (-40° to +149° F)
Humidity
Operating
20% to 80% relative humidity,
non-condensing
Non-operating 5% to 95% relative humidity,
non-condensing
Altitude
Operating -30 to 3,045 m (10,000 ft)
Non-operating -30 to 12,180 m (40,000 ft)
Thermal Output
Maximum Operating
1,365 BTU/hr
NOTE The specifications and requirements listed above can vary if
you install a mass storage device in the HP Netserver that has
more stringent environmental limits than required for the
Netserver. Ensure the operating environment for any mass
storage devices you intend to install are compatible with the
Netservers environmental requirements.
Table A-3. Weight and Dimensions
Weight
38 lbs. (17.3 kg.) fully loaded (6 SCSI HDDs, 2
processors, and 4 DIMMs); excludes keyboard,
mouse, and monitor
Height
3.36 inches (85.4 mm)
Width
16.8 inches (428 mm)
Depth
23.3 inches (591 mm)