HP NetServer LPr Quick Service Reference Guide Last Updated: April 1999
Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
HP NetServer LPr System Information Front Panel Controls CD-ROM Drive Reset Switch Power ON/OFF LED Power On/Off Switch Drive Activity LED Power ON/OFF Switch Drive Error LED Drive Activity LED Drive Error LED Fan Failure LED Hot Swap Drive Shelf SCSI ID #0 Over-temperature LED Hot Swap Drive Shelf SCSI ID #1 Control / Indicator Floppy Disk Drive Power ON/OFF Reset LED Switch Over-temperature LED Fan Failure LED Description / Definition Power On/Off Switch Momentary switch.
Rear Panel Controls, Ports, and Indicators Power Inlet PCI slot 3 PCI slot 2 PCI slot 1 Network (PCI slot 4) Link LED Activitity LED 100 mbps LED Management Port Mouse Ultra SCSI Keyboard Monitor Indicator Definition Link LED This LED goes on to indicate that both the network adapter in the LPr and the network switch are receiving power and that they are properly connected. Activity LED This LED flashes to indicate data transfers to/from the LPr network adapter.
Memory The NetServer LPr's main memory is implemented with 5V SDRAM DIMMs (Dual In-Line Memory Modules). The NetServer LPr ships with at least 64 MB of main memory and supports up to 1 GB. Memory is available in the following DIMM capacities: 64, 128, and 256 MB. There are four DIMM sockets on the system board. DIMMs may be installed in any combination in any socket. However, we recommend starting at socket 0 and filling the sockets in numerical order: 1, 2, and 3. Use only HP DIMMs.
Boot Device Priority By default, the HP NetServer searches for bootable devices in the order shown below. CD-ROM Drive • Floppy Disk Drive • Embedded SCSI Controller, starting with SCSI ID 0 • PCI Slots in the order 3, 2, and 1 On each controller, the server scans for a boot device starting at device ID 0 and works up from there. The controller is always SCSI ID 7. NOTE This boot order can be changed using the SETUP utility (press [F2] during the boot process).
Remote Control Card Refer to the Top Tools Administration Guide for Remote Control along with the upgrade kit documentation for information on the remote control card. Route cable through open spaces to PCI area. DO NOT route the cable over the top of sheet metal walls. 2 IPMI/ I C Connector HP NetRAID Card NOTE If there are other SCSI controllers on the PCI bus, the slot will affect boot order. See the Boot Device Priority.
I/O Board Terminator Block Embedded SCSI Connector SCSI Cable Connector Processor Module NOTE Be sure that the VRM and the processor module associated with it are both in primary or secondary slots.
Exploded Views 7
Replaceable Parts List * This part is not on an exploded view.
16 Battery 5183-6570 17 Video memory 1818-6527 18 Network adapter card (NIC) D5013-63001 19 Rear panel 20 SCSI repeater card 21 PCI stabilizer (not orderable) 22 PCI access door (not orderable) 23 Power supply D6129-63003 24 Bezel kit (HP pictured) D6130-60002 Bezel kit, 3rd party D6130-60003 System board D6129-63001 25 (not orderable) D6129-63006 D6129-69003 D6129-69001 Cables Cable Part Number SCSI Terminator Power 5183-7652 I2C 5183-6815 Management Port 5183-6816
System Switches System Switches Default Settings On = Clear Password (6) On = Clear Config (5) Off On Off On Must Be OFF (7 & 8) Off On 550 Off On 500 Off On Off On 450 Off On 400 Off On CPU Frequency (MHz) 350 Specifications Temperature Operating 5°to 35°C (41°to 95°F) Non-operating Humidity (non-condensing) Operating -40° to +65° C (-40° to +149° F) 20% to 80% relative humidity, non-condensing Non-operating 5% to 95% relative humidity, non-condensing Operating -30 to 3,000 m (~ 10,
Notes: 11
1