HP Netserver LXr 8000 RS12/FC Config Guide for Windows NT4.0 Clusters

2
SPU
Model HP NetServer LXr 8000
Clock speed 400/450, 500/550 MHz
No. of CPUs 2 – 4
BIOS version Rel 10 or later
CPU cache Any size
RAM 256 MB minimum. Must be HP.
No. of power supplies 3
Local storage See
Local Storage below.
I/O slots: P8 – P7 Host Bus Adapter
P8 – P2 Client LAN
P7 – P1 Intra-cluster (Heartbeat) LANs
P2 – Remote card (optional)
NOTE The Client LAN must be installed in a higher PCI slot than the
Intra-cluster LAN.
Storage
Local
Controller
May Use - Embedded SCSI, NetRAID-1Si or NetRAID-3Si in PCI slot
P1, otherwise any controller listed on the HP Tested Products List.
May Not Use - NetRAID-1 or NetRAID-3
Driver 2.24
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack Storage/12FC (Required)
Host Bus Adapter
Model HP D8602A
No. of HBAs 1
Driver 1.12 or later
SPU I/O slot P8 or P7
RAID level 0, 1, 3, 5, or 0 & 1
Cabinet
RAID arrays Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets 1
FC Array Cards
Model D5990A
No. of cards/cabinet 1 - Simplex (Supplied with Rack Storage/12FC.)
2 - Duplex (Additional card required in the Rack Storage/12FC.)