HP Netserver LC 2000 FC Config Guide

2
For a SPOFless cluster, two D5013B NICs configured with AFT is
recommended.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable, or, configure as a VLAN through an
Ethernet switch. See Intra-cluster LAN below.
Power source Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version L.19.00 or later
Operating System
Service Pack
Microsoft Windows NT 4.0
SP6a or later
SPU
Model HP NetServer LC 2000
Clock speed 1000 MHz
No. of CPUs 2
BIOS version 4.06.29 PV or later
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 1 standard, 2 (for redundancy) required
Local storage See Local Storage below.
I/O slot Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order IDE CD-ROM, FDD, SCSI A, SCSI B, PCI-1, PCI-2, PCI-3, PCI-4,
PCI64-5, PCI64-6
M/S Certified
Configuration
M/S Certified Configuration:
P1 - Local storage ( NetRAID-1Si)
P3 - Client LAN ( D5013B)
P5 - Shared Storage HBA (D8602A)
Booted from NetRAID-1Si
Storage
Local
Controller May use embedded SCSI, NetRAID-3Si or NetRAID-1Si.
For SPOFless, recommend NetRAID-xSi with drives in RAID-1 mirror, or
another fault tolerant RAID level.
Driver For embedded SCSI, use sym_hi.sys version 4.12 or later.
For NetRAID-xSi, use mraidnt.sys version 2.24
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives Must be HP (hot swap or fixed)
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack
Storage/12FC
Required