hp netserver lh 6000 netraid-2m config guide - for Microsoft Windows 2000 A.S. Clusters PDF, 239K, 8/13/2001

LH60002K2M
8/13/01 3
Shared Storage Configuration
Parameter Specification
Enclosure
Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets One or two per NetRAID-2M controller (up to four per cluster)
Model Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID 5 (fixed)
Disk SCSI IDs 03, 815 (fixed)
Cables
SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See SCSI cabling diagram on page 5.
Power distribution
Layout Redundant power distribution units (PDUs) are recommended. See power cabling
diagram on page 6.
Microsoft
and HP Certified Server Configuration
Parameter Specification
Server
I/O controller PCI slot 6, NetRAID-2M shared storage controller
Network interfaces PCI slot 1, Client LAN
Embedded NIC for intra-cluster (heartbeat) LAN
Boot device Embedded DAC
Intra-Cluster (Heartbeat) LAN Configuration
Parameter Specification
Network
Connection HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication. It may
not be used for client communication.
NIC
Quantity One
Model Embedded NIC
Driver Hptxnt5.sys, version 4.02.27, or later
(driver obtained from Navigator CD-ROM L.20.00, or later)