HP Netserver LH Pro Surestore E Installation Guide

1
HP NetServer LH Pro
with
A3700AB HP SureStore E 12H Disk Array
Cluster Configuration Guide
10 October 1999
(see Version History at the end of this document)
Introduction
This document defines the supported HP NetServer LH Pro and A3700AB HP SureStore E 12H Disk Array
configurations for Microsoft Cluster Server. These configurations minimize single points of failure,
provide maximum availability, and have been certified by Hewlett-Packard and Microsoft. This guide is
prescriptive; it describes the configurations supported by HP. Any configuration not expressly allowed by
this guide will not be supported by HP.
What’s Defined
Cluster
SPUs
LANs
Local Storage
Shared Storage
Shared Storage Cabling
Cluster
Type of SPUs HP NetServer LH Pro 6/200 Model 1
Each node must be the same model SPU, but may have different
size main memory and cache.
Number of nodes 2
Shared Storage See Shared Storage below.
LANs:
Client LAN See Client LAN below.
Intra-cluster See Intra-cluster LAN below.
Power source Direct from power mains, power conditioner or uninterruptable
power supply (UPS) using any power conditioner or UPS.
System software:
Navigator version G.00.85 or later
Operating System Microsoft Windows NT Server 4.0, Enterprise Edition or later.
Service pack SP3 and hotfix “clusfixi” or later