HP Netserver LH Pro Surestore E Installation Guide

2
SPU
Model HP NetServer LH Pro 6/200 Model 1
Clock speed 200 MHz.
No. of CPUs 2 (at least two are required)
BIOS version 4.05.14 or later
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 2
Hot swap cages May use for local storage; but not use for shared storage.
Local storage Internal or external, using any controller. Must use HP disks. See
Local Storage below.
I/O slots: P9 - Shared storage HBA. See Shared Storage.
P7 - Intra-cluster LAN
P5 - Client LAN
all others - Any other plug-in cards.
LANs
Intra-cluster LAN Client LAN
LAN connection HP D5954A crossover cable or
any equivalent only
Any LAN
The intra-cluster LAN may
only be used for cluster node
communication via a crossover
cable. It may not be used for
client communication.
NIC:
Model HP D5013A (10/100TX PCI)
(or HP J3171A)
Any that is on both the HP Tested
Products List and the Microsoft
Hardware Compatibility List.
Driver 2.24.00.0000 or later Any driver
If the NIC used is the same as the
Intra-cluster LAN, then the Client
LAN must use the same driver as
the Intra-cluster LAN.
No. of NICs 1 1 minimum
SPU I\O slot P7 P5
Local Storage
Physical drive location SPU internal drive bays, or HP external drive cabinet (e.g., HP Storage
System/6), or any combination.
Disk drives Must be HP
Controller SPU embedded controller or any controller (any number, manufacturer
or driver) in any available I/O slot (see SPU I/O slots above).
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
Shared Storage
Host Bus Adapter