HP Netserver LP 2000r FC Config Guide for Windows 2000 Advanced Server Clusters

2
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable, or, configure as a VLAN through an
Ethernet switch. See Intra-cluster LAN below.
Power source Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDUs) are strongly recommended.
System software:
Navigator version L.20.00 or later
Operating System
Service Pack
Microsoft Windows
2000 Advanced Server
SP1 or later
SPU
Model HP NetServer LP2000r
Clock speed 1 GHz
No. of CPUs 2
BIOS version 4.06.16 or later
CPU cache Any size
RAM 256 MB minimum. Must be HP.
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind
the server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI
Microsoft
and HP
Certified
Configuration
P1 – Local storage (NetRAID-1M)
P2 – Shared Storage FC HBA (D8602B)
Booted from NetRAID-1M
Storage
Local
Controller May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M,
or NetRAID-2M
For SPOFless, recommend NetRAID-xM with internal drives in RAID-
5, or another fault-tolerant RAID level.
Driver
For embedded SCSI, use SYM_U3.SYS, version 5.07.00 or later.
For NetRAID-xSi, use MRAID35X.SYS, version 2.66 or later.
For NetRAID-xM, use MRAID2K.SYS version 5.20 (Navigator L.20.00
or later)
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives Must be HP (hot swap or fixed).
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack Storage/12FC Required - D5991A
Host Bus Adapter
Model HP Fibre Channel Host Bus Adapter - HP D8602B
No. of controllers 1
Driver HP D8602B - AFCW2K.SYS 3.0.3245.1