HP Netserver LPr Rack Storage/12FC Config Guide for Windows NT4.0 Clusters

2
Operating System Microsoft Windows NT Server 4.0, Enterprise Edition with Service Pack
SP6a or later
SPU
Model HP NetServer LPr
Clock speed 400, 450, 500, 550, 600, 650, 700 MHz. or higher
No. of CPUs 2
BIOS version 4.06.09 PR or later (400, 450 MHz with Rack Storage/12 D5989A)
4.06.14.PR or later (400, 450 MHz with Rack Storage/12 D5989B)
4.06.14.PR or later (500, 550 MHz with Rack Storage/12 D5989B)
4.06.29.PR or later (600, 650, 700 MHz with Rack Storage/12 D5989B)
CPU cache Any size
RAM 128 MB minimum. Must be HP.
Local storage See Local Storage below.
I/O slots Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4
M/S Certified
Configuration
P1 – Local storage (NetRAID 1Si)
P2 – Client LAN
P3 – Shared Storage HBA
P4 – Intra-cluster (Heartbeat) LAN
Booted from embedded SCSI
Storage
Local
Controller May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si.
Driver For embedded SCSI, use sym_hi.version 4.12 or later. For embedded DAC
and NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids Any
Shared
HP Rack Storage/12FC (Required)
Host Bus Adapter
Model HP D8602A
No. of HBAs 1
Driver Hhba5100.sys 1.12 or later
RAID level 0, 1, 3, 5, 10
Cabinet
RAID arrays Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets 1
FC Array Cards