Disk drives: HP 2.1 GB Hot-Swap Ultra SCSI Disk Module D3582C
HP 4.2 GB Hot-Swap Ultra SCSI Disk Module D3583C
HP 4.2 GB 10K rpm Hot-Swap Ultra SCSI Disk Module D4903A
HP 9.1 GB Hot-Swap Ultra SCSI Disk Module D4289A
HP 9.1 GB 10K rpm Hot-Swap Ultra SCSI Disk Module D6019A
HP 18.2 GB Hot-Swap Ultra SCSI Disk Module D5039A
RAID arrays A RAID array (logical disk) must be composed of all the same disk
model. Different size or speed disks are not allowed in the same RAID
array. Any combination of disk models is allowed on a SCSI channel.
Any combination of disk models is allowed in a cluster. RAID arrays
may not span NetRAID Adapters.
Cables HP Cluster Adapter D5957A
LANs
Intra-cluster (Heartbeat) LAN Client LAN
LAN connection HP D5954A crossover cable or any
equivalent only
Any LAN
The intra-cluster LAN may only be
used for cluster node
communication via a crossover
cable. It may not be used for client
communication.
NIC:
Model HP D5013A (10/100TX PCI)
(or HP J3171A)
Any that is on both the HP
Tested Products List and the
Microsoft Hardware
Compatibility List.
Driver 2.24.00.0000 or later Any driver
If the NIC used is the same as
the Intra-cluster LAN, then
the Client LAN must use the
same driver as the Intra-
cluster LAN.
No. of NICs 1 1 minimum
SPU I\O slot P2 P1