Chapter 13 Alternative Rack Mounting (4Post)
121
1. Lower the leveler screws on the racks lower four corners to make firm
contact with the floor. See Figure 13-4.
2. Ensure you have extended the anti-tip foot from the rack before continuing
this procedure. See Figure 13-4.
NOTE The HP Netserver weighs 32 lbs. (14.5 kg.) fully loaded. It is
not necessary to use two people when placing the Netserver
into the rack, but it may be helpful.
3. Lift the HP Netserver by its inner-rails off the floor or pallet.
4. Move the rear of the inner-rails mounted on the Netserver just beyond the
inside edge of the outer-rail assemblies. See Figure 13-6.
The mounting inner-rails should sit just inside the outer-rails with nothing
preventing the Netserver from moving into the outer-rails.
Figure 13-6. Mounting the HP Netserver
5. Slowly move the Netserver chassis into the outer-rail assemblies until the
Netserver is completely in the rack. See Figure 13-6.