HP Netserver LP 1000r User Guide

Chapter 5 Installing Additional Boards
42
PCI Slot
Riser Board
Installed
Latch
Figure 5-5. Inserting PCI Board-Riser Board
12. Insert the PCI board and riser board into the PCI connector on the system
board. See Figure 5-5.
13. Secure the PCI board into the slot opening between the two tabs and close
the latch. See Figures 5-4 and 5-5.
14. If you have a longer PCI board, you must use the board clamp to install the
board into the Netserver. See Figure 5-6.
a. Raise the board clamp before installing the PCI board. See Figure 5-6.
b. Install the PCI board into the Netserver, securing the PCI board into the
slot opening between the two tabs. See Figures 5-4 and 5-5.
c. Lower the PCI board onto the tab rests. See Figure 5-6.
d. Close the latch and then close the board clamp onto the edge of the PCI
board. See Figure 5-6.
15. When you have completed the PCI aboard installation, close the Netserver
and return it to the rack where power can be applied.