HP Netserver LXr Pro NetRAID Installation Guide

22
Reboot System B
System B has been on hold at the loader prompt. Reboot System B.
The HP NetRAID Express Tools displays its Management Menu.
Checking and Assigning Cluster Drive Letters
To check and assign drive letters at System B:
1. From the Windows NT Start menu, choose Programs|Administrative Tools|Disk
Administrator.
Windows NT Disk Administrator scans the disk array and displays the shared disks you initialized using
System A.
NOTE In the sample display note that System B assigned sequential drive letters E and F to the
drives. System B will not recognize the X and Y assignments that you made using
System A. However, they will have the same Volume Label that you assigned.
Disk Administrator, Scanned Drive Letters using System B
2. Click a disk box to select one of the disks that includes an array to be shared by the cluster.
Disk Administrator highlights the selected disk.
3. Select Tools from the pull-down menu, and choose Assign Drive Letter.
4. If the drive letter for the disk box matches that assigned with System A, simply click OK. If the drive
letter is different, select or type the drive letter that matches the System A drive letter and click OK.
Disk Administrator updates the disk driver letter assignment and makes the assignment permanent.