HP Netserver LXr Pro NetRAID Installation Guide

2
System software:
Navigator version G.01.00 or later
Operating System Microsoft Windows NT Server 4.0, Enterprise Edition or later
Service pack SP3 and hotfix "clusfixi", or later
SPU
Model HP NetServer LXr Pro Model 1
Clock speed 200 MHz.
No. of CPUs 2 – 4 (at least 2 are required)
BIOS version 1.00.09CD0L or later
CPU cache Any size
RAM 128 MB minimum. Must be HP.
No. of power supplies 3
Local storage Internal or external, using any controller. Must use HP disks. See
Local
Storage below.
I/O slots: P4 – P6 Shared storage controller
P3 or P4 - NetRAID local storage
P2 – Intra-cluster (Heartbeat) LAN
P1 – Client LAN
All others - Any other plug-in cards.
Storage
Local
Physical drive location SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/8)
Disk drives Must be HP
Controller SPU embedded controller or any controller (any number, manufacturer or
driver) in any available I/O slot. Use P3 or P4 for NetRAID local storage.
See SPU I/O slots above.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared
Controller
Model HP NetRAID Adapter D4943A
Use with HP Rack Storage/8 (D4902A) and HP Cluster Adapter only.
No. of controllers 1 - 2
Firmware S.01.00
Driver 2.03
NetRAID Assistant A.01.09
SPU I/O slot P4 - P6
SCSI ID 6, 7
Channels 0 and 1 only
Do not use channel 2 for any purpose.
RAID level 1, 5, 10, and 50 only
Logical disks 1 per RAID array
6 maximum per NetRAID adapter