HP Netserver LXr Pro NetRAID Installation Guide

3
Configuration
options:
Cluster mode on (cache write-through, no hot spare)
Ultra SCSI disabled
Termination: wide channel or automatic
Set any other options as you prefer
Cabinet
Model HP Rack Storage/8 D4902A
No. of cabinets 1 - 4
Disk drives: HP 2.1 GB Hot-Swap Ultra SCSI Disk Module D3582C
HP 4.2 GB Hot-Swap Ultra SCSI Disk Module D3583C
HP 4.2 GB 10K rpm Hot-Swap Ultra SCSI Disk Module D4903A
HP 9.1 GB Hot-Swap Ultra SCSI Disk Module D4289A
HP 9.1 GB 10K rpm Hot-Swap Ultra SCSI Disk Module D6019A
HP 18.2 GB Hot-Swap Ultra SCSI Disk Module D5039A
RAID arrays A RAID array (logical disk) must be composed of all the same disk model
(i.e., part number and suffix). Different size or speed disks are not allowed
in the same RAID array. Any combination of disk models is allowed on a
SCSI channel. Any combination of disk models is allowed in a cluster.
RAID arrays may not span NetRAID Adapters.
Cables HP D5957A Cluster Adapter. See Shared Storage Cabling below.
LANs
Intra-cluster (Heartbeat) LAN Client LAN
LAN connection HP D5954A crossover cable or any
equivalent only
Any LAN
The intra-cluster LAN may only be
used for cluster node communication
via a crossover cable. It may not be
used for client communication.
NIC:
Model HP D5013A (10/100TX PCI)
(or HP J3171A)
Any that is on both the HP
Tested Products List and the
Microsoft Hardware
Compatibility List.
Driver 2.24.00.0000 or later Any driver
If the NIC used is the same as
the Intra-cluster LAN, then the
Client LAN must use the same
driver as the Intra-cluster LAN.
No. of NICs 1 1 minimum
SPU I\O slot P2 P1