93
Fig Description Replacement Exchange
*
SCSI Slot Filler D5989-63004
*
HP Rail Kit D5989-60003
Specifications
Temperature
Operating
5° to 35° C (40° to 95° F)
Non-operating
–40° to 65° C (-40° to -140° F)
Humidity (noncondensing)
Operating 20% to 80% relative humidity
Non-operating Maximum 95% relative humidity
Altitude
Operating 3,046 m (10,000 ft)
Non-operating 12,200 m (40,000 ft)
Weight and Dimensions
Height 13.2 cm (5.19 in)
Width 46.36 cm (18.25 in)
Depth 71.76 cm (28.25 in)
Weight, chassis fully loaded 37.7 kg (83 lb)
Weight, chassis empty 15.9 kg (35 lb)
Power Requirements
Input voltage range
90-264 VAC
Frequency
47-63 Hz.
Typical AC input requirements for fully loaded configuration (73% of power supply capability):
Nominal Volts Amps Watts
100 5.48 537
120 4.51 530
200 2.61 512
230 2.25 507
Power supply type
Wide input range, power factor corrected
DC output power
500 Watts DC, continuous, maximum
Peak AC inrush current
30 Amps @ 230 VAC