HP Netserver Service Handbook, Volume 2 - Mid

95
DIMM Slot LED Blink Codes
LED Error Codes
= LED on = LED off
Alternating Blink Code:
LED LED LED LED
0 1 2 3
Error Condition Corrective Action
Primary VRM Failure
Check that primary voltage regulator module
(VRM) is correctly seated. If problem persists,
replace VRM.
Secondary VRM
Failure
Check that secondary VRM is correctly
seated. If problem persists, replace VRM.
Processor Over-
Temperature
Check fan for function. Turn off system, wait
20-25 minutes for system to cool, and restart
system.
Processor or
Terminator Board Not
Installed
Install processor in primary processor socket
and a processor or terminator board in
secondary processor socket.
DIMM Status Error Codes
When no processor error condition exists, each diagnostic LED display the status of the DIMM in the
corresponding socket, as follows:
OFF: no DIMM installed
Flashes ON and OFF at 1 Hz in 50/50 proportion of time: defective or inappropriate DIMM
Flashes ON and OFF at 1 Hz in 90/10 proportion of time: non-HP DIMM installed
ON: HP DIMM installed