HP Netserver Service Handbook, Volume 2 - Mid

115
Cables and Part Numbers
Cable Description Part Number
C62 Internal SCSI (Wide) LVD Cable (SCSI A to Primary Mass Storage) 5183-3444
C63 Internal SCSI (Wide) LVD Cable (DAC to Primary Mass Storage)* 5183-6527
C64 Internal SCSI (Wide) LVD Cable (DAC to Secondary Mass Storage)* 5183-6528
C65 Internal SCSI (Wide) LVD Cable (SCSI B to Secondary Mass Storage) 5183-6567
C72 Internal SE SCSI Cable 5183-3445
C73 External SCSI (Wide) LVD Cable (SCSI A or B to Rear Chassis) 5183-3446
D7 IDE CD-ROM Cable 5183-3442
F7 Flexible Disk Cable 5183-3443
P2 Primary Mass Storage Power Cable 5183-3448
P3
Secondary Mass Storage, Non-Hot-Swap Device,
CD-ROM, and Flexible Disk Power Cable
5183-3449
R1 Remote Management Cable 5183-2413
* Optional cable
Specifications
Temperature
Operating
5° to 35° C (41° to 95° F)
Non-operating
-40° to +65° C (-40° to +149° F)
Humidity (noncondensing)
Operating
20% to 80% relative humidity, non-condensing
Non-operating
5% to 95% relative humidity, non-condensing
Altitude
Operating
-30 to 3,000 m (~10,000 ft)
Non-operating
-30 to 12,000 m (~40,000 ft)
Minimum Clearance
Front
1 m (39 in)
Sides
2.5 cm (1.0 in)
Top
2.5 cm (1.0 in)
Back
15 cm (6.0 in)
Weight and Dimensions - LH 4
NOTE A fully-loaded NetServer can weigh up to 160 pounds (73 kg). Follow local safety
regulations, and use one person for every 40 pounds (18 kg) of NetServer weight
when lifting it.