HP Netserver Service Handbook, Volume 2 - Mid

159
Hot Swap Subsystem SCSI Address Settings
Switches 3, 4, and 6 determine the SCSI address setting for each shelf in the hot swap subsystem. The
following table describes the settings and the resulting shelf SCSI address.
NOTE For information on changing the SCSI address setting on the CD-ROM drive, see the
Technical Information Label on the CD-ROM drive.
Upper Cage Lower Cage
Switch
Settings
SCSI Address Switch
Settings
SCSI Address
3 - Off
4 - Off
6 - Off
Shelf 1 = ID 1
Shelf 2 = ID 2
Shelf 3 = ID 3
3 - Off
4 - Off
6 - On
Shelf 4 = ID 4
Shelf 5 = ID 5
Shelf 6 = ID 6
3 - Off
4 - On
6 - Off
Shelf 1 = ID 1
Shelf 2 = ID 0
Shelf 3 = ID 3
3 - Off
4 - On
6 - On
Shelf 4 = ID 4
Shelf 5 = ID 0
Shelf 6 = ID 6
3 - On
4 - Off
6 - Off
Shelf 1 = ID 9
Shelf 2 = ID 10
Shelf 3 = ID 11
3 - On
4 - Off
6 - On
Shelf 4 = ID 12
Shelf 5 = ID 13
Shelf 6 = ID 14
3 - On
4 - On
6 - Off
Shelf 1 = ID 9
Shelf 2 = ID 8
Shelf 3 = ID 11
3 - On
4 - On
6 - On
Shelf 4 = ID 12
Shelf 5 = ID 8
Shelf 6 = ID 14
Specifications
Power Supply
Auto-ranging 90 to 135 VAC, or 180 to 265 VAC at 50-60Hz
Power Availability
470W continuous, 530W peak
Power Consumption
723W maximum with 110/220V supply
815W peak with 110/220V supply
System Dimensions
19.3 in. high x 13.7 in wide x 18.1 in deep
(49 cm high x 34.8 cm wide x 46 cm deep)
System Weight
50-70 lbs (22.7-31.8 kg), depending on configuration
Operating Temperature
41 to 95 degrees F (5 to 35 degrees C)
Operating Humidity
20% to 80% non-condensing