HP Netserver Service Handbook, Volume 2 - Mid

90
Hot Swap Subsystem SCSI Address Settings
Switches 4 and 6 determine the SCSI address setting for each shelf in the hot swap subsystem. The
following table describes the settings and the resulting shelf SCSI address.
NOTE For information on changing the SCSI address setting on the CD-ROM drive, see the
Technical Information Label on the CD-ROM drive.
Upper Cage Lower Cage
Switch
Settings
SCSI Address
Switch
Settings
SCSI Address
3 - Off
4 - Off
6 - Off
Shelf 1 = ID 1
Shelf 2 = ID 2
Shelf 3 = ID 3
3 - Off
4 - Off
6 - On
Shelf 4 = ID 4
Shelf 5 = ID 5
Shelf 6 = ID 6
3 - Off
4 - On
6 - Off
Shelf 1 = ID 1
Shelf 2 = ID 0
Shelf 3 = ID 3
3 - Off
4 - On
6 - On
Shelf 4 = ID 4
Shelf 5 = ID 0
Shelf 6 = ID 6
Specifications
Power Supply
Auto-ranging 90 to 132 VAC, or 180 to 264 VAC at 47-63Hz
Power Availability
LH/LH Plus 350W continuous, 386W peak
LH Pro 450W continuous
Power Consumption
LH/LH Plus: 499/479W maximum with 110/220V supply
551/528W peak with 110/220V supply
LH Pro: 650/600 maximum with 110/220V
System Dimensions 19.3 in. high x 13.7 in wide x 18.1 in deep
(49 cm high x 34.8 cm wide x 46 cm deep)
System Weight
50-70 lbs (22.7-31.8 kg), depending on configuration
Operating Temperature
41 to 95 degrees F (5 to 35 degrees C)
Operating Humidity
20% to 80% non-condensing
BTUs
LH/LH Plus: less than 1700 BTUs (430 Kcal)
LH Pro: less than 2200 BTUs (560 KCal)