HP NetServer LPr Installation Guide for Compaq® 4000/7000 Racks HP Part Number 5967-6635 Printed in October 1998
Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Contents 1 Introduction ...................................................................................................... 3 HP NetServer LPr – Compaq Rack Precautions ............................................... 5 2 Overview ........................................................................................................... 7 3 Installation ........................................................................................................ 7 Preparation ...................................
1 Introduction This document describes how to mount an HP NetServer LPr into a Compaq® model 4000- or 7000-series rack enclosure. Refer to the HP NetServer LPr Installation Guide that came with the NetServer for instructions on adding accessories to and configuring the NetServer. The HP NetServer LPr is shown in Figure 1-1. Figure 1-1.
Introduction at the front of the base of the enclosure and, if you are installing this NetServer in a single rack enclosure, two "feet" each on the left and right sides of the enclosure (see Figure 1-2). Side Stabilizing "Feet" (Both Sides) Front Stabilizing "Feet" Figure 1-2.
Introduction HP NetServer LPr – Compaq Rack Precautions CAUTION If this NetServer is not installed according to these instructions, damage to the NetServer or accessories may result. Damage due to improper installation is not covered by the HP Warranty. Observe the precautions listed in this section to maintain the NetServer’s reliability. When the HP NetServer LPr is installed in a Compaq rack enclosure, certain requirements must be addressed to assure that the needs of the NetServer are met.
Introduction 2 Overview The steps required to install the NetServer in the rack are summarized below: NOTE This is only a summary; detailed instructions are provided on the following pages. • Measure and mark the appropriate holes on all four rack columns. • Install three rack nuts on each of the two front rack columns. • Insert one rack nut on each of the two rear rack columns. • Attach the rails to the columns. • Slide the NetServer onto the rails. • Secure the NetServer to the two front columns.
Installation
Installation 3 Installation This section contains detailed instructions for installing an HP NetServer LPr in certain models of Compaq rack enclosures. Preparation Before beginning the installation of the NetServer into the rack, you must prepare the rack and the NetServer. Determine the location at which the NetServer is to be installed in the rack enclosure. Mark the bottom and top of this location on the rack columns. The HP NetServer LPr measures 2 EIA units tall.
Installation 3rd 3rd (At Rear Of Column) 5th 3rd 2nd 5th 3rd 2nd Template (optional) Unit Below Intended Installation Location Figure 3-1. Marking Holes For Installation To mark the NetServer mounting holes on the front columns (refer to Figure 3-1), count up from the top of the unit below, marking the 2nd and 5th holes. Installing the Rack Nuts Once you have marked the holes, install one supplied rack nut in each hole (previously marked) on all columns (see Figure 3-2).
Installation Rack Column Rack Nut Figure 3-2. Installing Rack Nuts Mounting the Rails 1. Slide the two halves of each rail together (see Figure 3-3). Use either rail in either location; they are identical.
Installation Figure 3-3. Rail Assembly 2. Position a rail so that the mounting flanges align with the installed rack nuts (see Figure 3-4). Do this at the front and rear columns. 3. Insert a screw in the second hole from the bottom of each flange and tighten the screw. 4. Repeat for the other rail.
Installation Front Column Rack Nuts Rail Flange Figure 3-4. Mounting a Rail To a Column Installing the NetServer WARNING To prevent the rack from tipping over, be sure that the stabilizing, anti-tip feature is installed on this rack enclosure (see Figure 1-2). 1. Remove the hot-swap disk modules from the NetServer before lifting it into the rack enclosure. WARNING Use two people when moving the NetServer or lifting it into the rack. 2.
Installation Figure 3-5.
Installation 3. Install two screws through the two holes on either side of the NetServer front panel (see Figure 3-6) and into the rack nuts in the columns (previously installed). Figure 3-6. Securing the NetServer to the Rack Columns 4. Replace the hot-swap disk modules into the NetServer. Installing the Bezel This NetServer ships with bezel anchors for use with an HP-rack bezel. In order to install the bezel for use with a Compaq rack, the HP-bezel anchors must be replaced with Compaq-bezel anchors.
Installation Figure 3-7. Removing the Bezel Anchors from the NetServer 2. Attach the bezel anchors to each side of the NetServer front panel using two screws (see Figure 3-8). Figure 3-8.
Installation 3. Attach the bezel for use with the Compaq rack to the NetServer (see Figure 3-9). Figure 3-9.
4 Warranty and Support Refer to the warranty and service/support booklet provided with your HP NetServer for details on the warranty limitations, customer responsibilities, and other terms and conditions. CAUTION Improper installation of HP rack mount components into third party racks may result in unreliable operation or damage to the HP components. Repairs to HP components due to improper installation into third party racks are not covered under the HP warranty.