5190/5194 Modular Tape Subsystem Manual
Installing the Modular Tape Subsystem
5190/5194 Modular Tape Subsystem Manual—426878-002
3-52
Troubleshooting the Modular Tape Subsystem
(NonStop Himalaya S-Series Servers)
Troubleshooting the Modular Tape Subsystem
(NonStop Himalaya S-Series Servers)
The following troubleshooting tables help you identify and correct problems that can
occur when you install the modular tape subsystem. Each table addresses a specific
problem, lists symptoms related to the possible cause of the problem, and lists actions
you can take to correct the problem. In general, if you suspect a hardware problem, do
the following:
1. Use TSM to check the hardware. For the 6760 adapter, TSM test procedures are
described in the 6760 ServerNet/DA Manual.
2. Use the SCF STATUS ADAPTER, DETAIL command to check the status of all
paths to the adapter and its attached devices.
3. Use the SCF INFO ADAPTER, DETAIL command to verify proper configuration.
If you need further help solving an installation problem, call your service provider.
ACL Door Does Not Open
Symptom Corrective Action
ACL door does not open when ACL is
powered down.
1. Apply power to the tape drive CRU, unload
any cartridge in the drive, and reset the ACL
by pressing the RESET button until the
asterisk (*) appears on the message panel.
Then open the door.
2. Defeat the door lock mechanism manually.
See Unlocking the ACL Door When Power Is
Removed on page 4-20.
ACL Does Not Function Properly
Symptom Corrective Action
ACL does not respond to commands, or
it functions abnormally.
Contact your service provider.