5190/5194 Modular Tape Subsystem Manual

Installing the Modular Tape Subsystem
5190/5194 Modular Tape Subsystem Manual426878-002
3-9
Environmental Requirements
Environmental Requirements
Table 3-5 lists environmental requirements for the tape drive module.
Fiber-Optic Cable Installation
You use the same kind of fiber-optic cable to attach a tape drive CRU to a 3216
controller or a 6761 fiber-optic plug-in card (F-PIC) on a 6760 adapter. Part numbers
for the different cable lengths are listed in Appendix A, Part Numbers. The procedures
in this section assume that the fiber-optic cable has been installed by a certified cable
installer. Within the U.S., installation support can be obtained through your service
provider. Services are available for virtually every aspect of the installation process,
including site survey, construction and safety permits, cable selection, installation,
terminations, and testing.
For an installation performed by personnel not employed by Compaq, your service
provider can certify that the minimum requirements are met for proper system
operation. To take advantage of these services, contact your service provider.
AC Power Requirements
Each 5190 and 5194 tape drive CRU contains an auto-ranging power supply that
accepts input current in two voltage ranges: 85–132 volts AC (3.0 amperes) and
170–264 volts AC (1.5 amperes). No switch is required to change between ranges or
between 50 and 60 hertz. Table 3-6 shows the tape drive CRU AC power
requirements.
Table 3-5. Environmental Requirements for the Tape Drive Module
Factor Operating* Nonoperating In Transit
Temperature 15 to 32 °C
(60 to 90 °F)
-29 to 55 °C
(-20 to 131 °F)
-40 to 66 °C
(-40 to 150 °F)
Temp. gradient (maximum) 11 °C (20 °F)/h 11 °C (20 °F)/h 11 °C (20 °F)/h
Relative humidity (noncondensing) 20 to 80% 10 to 95% 10 to 95%
Shock (11 ms duration) 3 G 10 G 10 G
Audible noise 55 dB n/a n/a
Heat output (module with two drives
and two ACLs)
1700 Btu/h n/a n/a
* Operating temperature and humidity are limited by the media specification.
Table 3-6. AC Power Requirements for the Tape Drive CRU
Power Volts Amperes
USA 60 Hz 110/120 3.0
Europe 50 Hz 220 1.5
Orient 50 Hz 200 1.5