5525B/31/32 Line Matrix Printer Code V Programmer's Reference Manual

180
Chapter 3 Bar Codes
Readable Data
The optional readable data field provides a readable interpretation of the bar
code data. Readable data is printed below the horizontal bar code symbol,
and to the left of a vertical bar code symbol. The lower guard band is provided
when the readable data field is selected.
Check Digit
The check digit provides the means of verifying accurate scanning. For MSI
Types G, H, I, and X, a specific check digit, Modulo-10 or Modulo-11 (or both),
is automatically calculated and appended in the bar code symbol. MSI Type F
does not use a check digit.
Standard MSI Command Format
Refer to page 135 for the IBARC, command format and definitions.
Default Ratio: (cc)
dir p type data
(cc)G
Variable Ratio: (cc)
dir p
[9] [:]
type
[
ratio
]
data
(cc)G
(cc) Represents the Special Function Control Code
(SFCC). Enter the specific SFCC for your Code V
configuration.
dir
Represents the direction of the bar code. Enter B
for horizontal or C for vertical bar codes.
p
Prints the optional readable data field. The
readable data field is printed below a horizontal bar
code or on the left-hand side of a vertical bar code.
Replace
p
in the bar code command with one of the
codes listed in Table 33 to print the readable data
field in the corresponding font with the specified
guard band gap.
9 or : Optional parameter to select a variable ratio bar
code. Enter the number 9 to select a variable ratio
bar code. This feature overrides the MSI default
ratio 1:1:2:2.
Table 33. Printable Data Field Fonts
Font Gap
p
code
Standard 10 cpi 3 dots Y
OCR-A 3 dots O
OCR-A .1-inch S
OCR-B 3 dots B
OCR-B .1-inch T
None N