5525B/31/32 Line Matrix Printer Code V Programmer's Reference Manual
POSTNET
187
Standard POSTNET Command Format
Default Ratio: (cc)
dir
[N]
*
data
(cc)G
(cc) Represents the Special Function Control Code
(SFCC). Enter the specific SFCC for your Code V
configuration.
dir
Represents the direction of the bar code. Enter B
for horizontal bar codes. Enter C for vertical bar
codes.
N Provides a switch to turn off the readable data field.
N or no input are the only options.
* Type code for POSTNET. Enter *.
data
The bar code data. POSTNET bar codes encode
exactly 5, 9, or 11 numeric digits. A check digit is
automatically added by the IGP.
(cc)G Terminates the bar code command. Enter the
SFCC for your Code V configuration immediately
followed by any valid command character or G, the
universal sequence terminator.
NOTE: The POSTNET bar code symbol height is fixed at 0.125 inches.
POSTNET Example
^PY^-^M^KF^
BN*927047563^G^
KF^-^PN^-