Chapter 4 Label Example
Add Horizontal Lines
9. The three horizontal lines to separate the three bar code fields can be
added to the form using Justification (J), Horizontal Tab (T) and Solid Line
(LS) commands. All three lines are 2.6 inches plus 4 dots horizontally
(
horz
) and 1 dot vertically (
vert
), used as the line thickness, and all three
lines are tabbed 0.0 inches (
dis
) from the left margin (touching the left
edge of the label). Justify the first line 1.9 inches down (
jus
), the second
line 2.8 inches down, and the third line 3.7 inches down.
Format: (cc)J
jus
(cc)T
dis
(cc)LS
horz vert
Enter: ^J190^T0000^LS0264,0001
^J280^T0000^LS0264,0001
^J370^T0000^LS0264,0001
Add Headings
10. The Sales Order (S.O.), Serial Number (S/N), and the Part Number (P/N)
headings can be added using a series of Justification (J) and Horizontal
Tab (T) commands. Each of the headings are tabbed 0.4 inches (
dis
)
from the left margin. Justify the S.O. heading 2.0 inches (
jus
) down, the
S/N heading 2.9 inches down, and the P/N heading 3.8 inches down.
Format: (cc)J
jus
(cc)T
dis data
Enter: ^J200^T0040S.O.
^J290^T0040S/N
^J380^T0040P/N
Add Bar Codes and Dynamic Bar Code Data
11. The three bar codes and dynamic bar code data fields can now be input.
A Standard Alphanumeric command (M) is used to specify each bar code
height at 0.6 inches (
ht
) and width (
wd
) at 0.1 inch. The actual width of the
bar code is determined by the type of bar code, the data, and the ratio.
The S.O. bar code is justified 2.1 inches plus 3 dots (
jus
) down, the S/N
bar code 3.0 plus 3 dots down, and the P/N bar code 3.9 plus 3 dots
down. Each bar code is tabbed 0.4 inches (
dis
) from the left margin using
a Horizontal Tab command (T).
The horizontal Bar code command (B) with fixed ratio is used, the
printable data field is selected (
p
) to produce human readable data using
OCR-B characters with the bar code, and bar code type (
type
) Code 39 is
selected for use. The Dynamic Form Field Length command ([) specifies
a maximum of 6 data characters for each bar code.
Format: (cc)M
ht wd jus
T
dis data
(cc)B
p type
(cc)[
length
(cc)G
Enter: ^M06,01,213^T0040
^BOA^[006^G
^M06,01,303^T0040
^BOA^[006^G
^M06,01,393^T0040
^BOA^[006^G