5525B/31/32 Line Matrix Printer Code V Programmer's Reference Manual
Boxes
 31
Boxes
Purpose Produces a variety of rectangular boxes.
Mode Graphics with an Extended Graphics Command selected
Format (cc) LB 
horz vert h v 
(cc)-
(cc) Represents the Special Function Control Code 
(SFCC). Enter the specific SFCC for your Code V 
configuration.
LB The Box command. Enter LB.
horz
Defines the horizontal length of the box in tenth 
inches and dot columns. Enter a three-digit 
horizontal length value ranging from 000 through 
999 to define a horizontal length of 00.0 through 
99.9 inches and a fourth digit ranging from 0 
through 9 to specify 0 through 9 additional dot 
columns of length. The Code V automatically 
understands the decimal between the second and 
third digits for tenth inches and automatically 
interprets the fourth digit as dot columns. For 
example, entering 0126 specifies a 1.2-inch plus 6-
dot column horizontal length; entering 1016 
specifies a 10.1-inch plus 6-dot column horizontal 
length.
vert
Defines the vertical length of the box in tenth inches 
and dot rows. Enter a three-digit vertical length 
value ranging from 000 through 999 to define a 
vertical length of 00.0 through 99.9 inches and a 
fourth digit ranging from 0 through 9 to specify 0 
through 9 additional dot rows of length. The Code V 
automatically understands the decimal between the 
second and third digits for tenth inches and 
automatically interprets the fourth digit as dot rows. 
For example, entering 0204 specifies a 2.0-inch 
plus 4-dot row vertical length; entering 0242 
specifies a 2.4-inch and 2-dot row vertical length.
h
Defines the horizontal border thickness in dot 
columns. Enter a one-digit horizontal value ranging 
from 1 through 9 to define a horizontal thickness of 
1 through 9 IGP dots.
v
Defines the vertical border thickness in dot rows. 
Enter a one-digit vertical value ranging from 1 
through 9 to define a vertical thickness of 1 through 
9 IGP dots.
(cc)- Graphics Mode CR used as a sequence terminator. 
Enter the SFCC for your Code V configuration 
immediately followed by - to end the command 
sequence.