b. Replace 
n
 with a number ranging from 1 
through 512 to identify the bar code field. The 
SR
 and 
SC
 parameters specify the exact 
location of the bar code field identified by 
n
.
c. Replace 
L
 with the maximum number of 
characters in the field. The actual data 
provided dynamically during the Execute Form 
mode can be less than 
L
. It is permitted to 
supply no data at all.
d. The information for the data field is entered 
dynamically during the Execute Form mode. 
(Refer to “Execute Form: Dynamic Bar Code 
Data” on page 63.) Do not use the 
data field
parameter to enter data when the BF
n;L
parameters are used. However, refer to the 
data field
 description for available characters 
to use during Execute Form mode.
DARK Optional parameter to produce darker bar codes. 
Enter DARK. Refer to “Dark Printing” on page 28 
for more information.
SR
Defines the starting row for the bar code. Enter a 
value ranging from row 1 to one less than the 
length of the form. Character row or dot row is 
specified based on the Scale command, or use the 
CP.DP format.
SC
Defines the starting column of the bar code. Enter a 
value ranging from column 1 to one less than the 
width of the form. Character column or dot column 
is specified based on the Scale command, or use 
the CP.DP format.
(D)
The printable character (delimiter) identifying the 
start and finish of the data field. Enter any printable 
character other than a slash (/), the SFCC, or a 
character used within the data. The same character 
must be used on both ends of the data field. It will 
not print with the data.
data field
The bar code data. The data field for UCC/EAN-
128 consists of an “application identifier” (AI) of two 
to four numbers, followed by data of appropriate 
length (variable or fixed) and type (numeric or 
alphanumeric). See Table 17 for a list of application 
identifiers and their associated data fields.
The FNC1 character is required as the first 
character after the start code for UCC/EAN-128 bar 
codes, and IGP/PGL will always generate it 
automatically. It will appear in the bar code but not 
in the human readable field. Do not supply FNC1 in 
the data field. 