5525B/31/32 Line Matrix Printer IGP/PGL Programmer's Reference Manual
Codabar
 95
SR
Defines the starting row for the bar code. Enter a 
value ranging from row 1 to one less than the 
length of the form. Character row or dot row is 
specified based on the Scale command (page 82), 
or use the CP.DP format (page 26).
SC
Defines the starting column of the bar code. Enter a 
value ranging from column 1 to one less than the 
width of the form. Character column or dot column 
is specified based on the Scale command (page 
82), or use the CP.DP format (page 26).
(D)
The printable character (delimiter) identifying the 
start and finish of the data field. Enter any printable 
character other than a slash (/), the SFCC, or a 
character used within the data. The same character 
must be used at both ends of the data field, but it is 
not printed with the data.
data field
Contains the bar code characters. A null data field 
(no characters) is permitted. The data field can 
contain any of the characters listed in Table 10 
except the SFCC. The length of the data field is 
variable; however, the maximum length is usually 
limited to 32 characters to minimize potential 
reading errors.
PDF Optional parameter to enable printing of the human 
readable data field. Enter PDF to print the data 
field. If the parameter is not used, the human 
readable data will not print. This parameter is not 
allowed if a null data field is specified.
LOC
Optional parameter to identify the location of the 
printable data field. The default value is B, locating 
the human readable data below the bar code. A 
locates the printable data field above bar code. To 
compensate for printing the 0.1-inch high data, the 
height of the bar code body is reduced 0.1 inch. 
FONT
Optional parameter to select the font for the human 
readable data field. Enter O to select OCR-A font; 
enter X to select OCR-B font; enter N to select 10 
cpi; enter P to select 12 cpi; enter Q to select 13 
cpi; enter R to select 15 cpi; enter T to select 17 cpi; 
enter V to select 20 cpi.
STOP Ends the Bar Code command while the IGP/PGL 
continues in the Create Form Mode. Enter STOP. If 
STOP is not entered, an error message results.