5525B/31/32 Line Matrix Printer LinePrinter Plus Programmer's Reference
Initialize Parameters
79
n4
and
n5
Parameter bytes
n4
and
n5
allow you to define several configuration
parameters that will override conflicting factory default and memory-based
configuration values when the printer is reinitialized. Possible values for
n4
and
n5
are listed in Table 18 and Table 19, respectively.
NOTE: In addition to the formatting from bytes
n4
and
n5
, this command sets
the current line as top-of-form. It also clears vertical tabs and sets the
horizontal tabs at every eight columns, starting at column 9.
Table 18.
n4
Values
n4
Bit Function OFF (0) ON (1)
7 Process this byte Process Ignore
6 Reserved Reserved Reserved
5 n/a n/a n/a
4 Line Feed = LF LF + CR
(add CR with each LF)
3 Carriage Return = CR CR + LF
(add LF with each CR)
2 Set forms length 11 inches 12 inches
1 Slashed Zero Disable Enable
0 Character set 1 (A) 2 (B)
Table 19.
n5
Values
n5
Bit Function OFF (0) ON (1)
7 Process this byte Process Ignore
6 Code page 437 850
5 Unidirectional
Printing
Bidirectional Unidirectional
4 12 cpi compressed
to 20
20 12
3 n/a n/a n/a
2 Form feed at TOF Enable Ignore
1 Print Width 13.2 inches 8 inches
0 Sheet feeder n/a n/a