6100 ADCCP Programming Manual

(80) SET X.21 CONFIGURATION
Requests and Responses
6–40 069225 Tandem Computers Incorporated
(80) SET X.21
CONFIGURATION
The SET X.21 CONFIGURATION request and response are used to modify the X.21
configuration block in the LIU.
Request The SET X.21 CONFIGURATION request replaces values in the X.21 configuration
block in the LIU. Until you issue this request, ADCCP/X21 uses the default
configuration values. You can issue a SET X.21 CONFIGURATION request at any
time, but ADCCP/X21 does not implement any changes until the option is used.
To examine the current values before making a change, use the (81) FETCH X.21
CONFIGURATION request.
The request buffer format is:
Function := 80
Modifier := 0
Request ID := A unique value from 1 through 32767,
determined by the application
Text Out := 34
Text In := 1 if you want error detail returned,
0 otherwise
Text := CIRCUIT-SWITCHED :Byte
NOT READY STATE :Byte
ACCEPT CHARGES :Byte
RETRY MAXIMUM :Byte
RETRY INTERVAL :Word
CPS ACTION TABLE :Ten bytes
TIMELIMIT T1 :Word
TIMELIMIT T2 :Word
TIMELIMIT T3A :Word
TIMELIMIT T3B :Word
TIMELIMIT T4 :Word
TIMELIMIT T5 :Word
TIMELIMIT T6 :Word
TIMELIMIT T7 :Word
TIMELIMIT TL :Word
See “X.21 Line Configuration Options” in Section 3, “ADCCP/X21 Protocol Module,”
for a description of the parameters specified in the text field of the SET X.21
CONFIGURATION response .