6100 ADCCP Programming Manual

File-System Error Codes
File-System Error Codes
069225 Tandem Computers Incorporated A–5
Table A-1. File-System Error Codes– Do Not Retry (Page 2 of 2)
Error
Code Description/Solution
24 Nonresponding LIU; trying to reset. The LIU is not present in its slot, has not been powered
up, or is otherwise not working. (CP6100 issues a status probe every 10 seconds over the
primary path. This message means that there was no response to the most recent status
probe and that the CSM is trying to reset the LIU.) You may want to retry this request, in
case the reset succeeded. Otherwise, prepare the unit for operation—power it up and use
CMI to start it. This error can also indicate a loss of power to the BOB; prepare the BOB for
operation by restoring power to it.
60 Invalid open ID or not open. You made a request of a line or device without first opening it.
Either you forgot the OPEN call, a failure occurred during that call and you didn’t reissue it,
or the line was downloaded after being opened (with the SYSGEN AUTOCLOSE parameter
set). Open the line; if the line was downloaded after being opened, close it and open it
again.
61 Device suspended. The line or device is unable to accept OPEN requests. An operator
used CMI to suspend the device; have the operator activate the device, and then repeat the
operation.
66 Device down. The line or device cannot accept any requests; perhaps an operator used
CMI to stop the device, an error condition caused CP6100 to stop the device, or the line
interface unit has not been downloaded yet. This message can also mean that the protocol
rejected the configuration block. Check the console for messages about a possible
hardware failure. Ensure that there is power to the subsystem cabinet; then have the
operator use CMI to download and start the line interface unit; finally, repeat your request.
If the error persists, contact your Tandem representative.
99 No License for protocol software. There is probably something wrong with the software
license PROM. Contact your customer engineer.
100 Controller not operational. The controller is not present in its slot, is not addressed
correctly, has not been powered up, or has not been downloaded. Prepare the controller for
operation before you try the request again.
201 Error in message system interface. This message means CP6100 could not communicate
with the application. Possibly someone stopped both CPUs in which CP6100 was running;
repeat the request when CP6100 is running again. If the problem persists, call your
Tandem representative.
1160 Request invalid for line state. Probably an operator used CMI to stop, suspend, or
otherwise change the state of the line during your request. If no one was using CMI, the LIU
malfunctioned. Check the console for messages regarding a hardware failure; have the
operator use CMI to make the line accessible again, and reissue your request.