6100 ADCCP Programming Manual

6100 ADCCP Concepts and Context
Introduction to 6100 ADCCP
069225 Tandem Computers Incorporated 1–19
Table 1-2. Line Configuration Options
Error Handling Frame Format Line and Modem
Control
Character Code Transmission Transmission Control
L1RETRY AFLD DSRTIMER TRANSLATE ABMIPON°
L2RETRY EXTENDED FLAGIDLE XOFFSET ABMSUPPON°
NOREJ MAXFRAME HALFDUPLEX ADDRESS
SREJ XLENGTH IDLETIMER
T1TIMER SWINCARRIER MODE*
TESTFRAME° SWITCHED NOCARRFATAL
THRESHOLD SWINOUTCARRIER OPTIONA°
XFERTIMER OPTIONB
POLL
STATIONS
SUPRESSRR°
TWA
TWS
WINDOW
* Mode is set at system generation time through the ABMMODE, ARMMODE, or NRMMODE modifiers.
° Can be set only by using the (1) SET CONFIGURATION request.
A reserved byte in the configuration block.
Note Any parameter that you set for the local station must be consistent with the operation of the remote
station. In some cases, the settings must be identical. For example, line control mode and window size
must match on both sides of the link. In other cases, the settings must be complementary. For example,
if a primary has a switched input carrier, the other stations on the link must have switched output carriers.