6100 BSC Programming Manual

6100 BSC Concepts and Context
1
2
3
1
1
S5066-007
Starts
transparent
text mode
PAD SYN...SYN SOH DLE STX DLE ITB BCC SYN SYN DLE STX DLE ETX BCC PAD
DATA TEXT TEXT
PAD DLE STX DLE ETX BCC PADSYN...SYN TEXT
PAD SYN...SYN SOH DLE STX DLE ETX BCC PAD
DATA TEXT
PADSYN...SYN SOH STX PADETB BCC
DATA TEXT
PAD DLE STX DLE ETB BCC PADSYN...SYN
TEXT
PAD STX ETX BCC PAD
TEXT
BCC Accumulation
BCC Accumulation
This is the only transparent block in the message
PAD DLE STX ETX DLE DLE DLE ETB BCC PADSYN...SYN TEXT TEXT TEXT
This ETX is
regarded as
data
This DLE is
regarded as
data
This ETB is
recognized as
a control character
"Close up" of Transparent Block
"TEXT" may contain BSC control characters.
Only a text block can be transparent. A heading block can't.
All text blocks in this message are transparent. The heading is not transparent.
Legend
Application-Supplied
BSC-Supplied
1
2
3
Figure 1-7. Transparent Text
1-17