6100 BSC Programming Manual

6100 BSC Link and Station Management
-----------------------------------------------------------------
| |
| Original State: READ |
| |
| Request Status Code Description New State |
| |
| READ 140 Modem error DISCONNECTED |
| 161 6100 error DISCONNECTED |
| 162 Timeout CONTROL |
| 163 EOT received CONTROL |
| 164 DLE EOT received DISCONNECTED |
| 166 ENQ received CONTROL |
| 172 Format error in CONTROL |
| received data |
| 173 Bad BCC or other CONTROL |
| data error |
| 177 Received block CONTROL |
| too large |
| 190 6100 error DISCONNECTED |
| other READ |
| WRITEREAD 0 Normal completion: WRITE if ACK; |
| ACK or text READ if text |
| 140 Modem error DISCONNECTED |
| 161 6100 error DISCONNECTED |
| 162 Timeout CONTROL |
| 163 EOT received CONTROL |
| 164 DLE EOT received DISCONNECTED |
| 165 RVI received WRITE |
| 166 ENQ received CONTROL |
| 172 Format error in CONTROL |
| received data |
| 173 Bad BCC or other CONTROL if in |
| error in data data |
| sent or received received, |
| WRITE if in |
| data sent |
| 175 Invalid acknowl. WRITE |
| 177 Received block CONTROL |
| too large |
| 190 6100 error DISCONNECTED |
| other READ |
| CONTROL 0 Normal Completion DISCONNECTED |
| (DISCONNECT) 140 Modem error DISCONNECTED |
| 161 6100 error DISCONNECTED |
| 162 Timeout DISCONNECTED |
| 190 6100 error DISCONNECTED |
| (WACK) 140 Modem error DISCONNECTED |
| 161 6100 error DISCONNECTED |
| 190 6100 error DISCONNECTED |
| other READ |
| |
-----------------------------------------------------------------
Figure 2-5. Status Codes to Leave READ State
2-17