6100 BSC Programming Manual
 6100 BSC Link and Station Management
 -----------------------------------------------------------------
 | |
 | Original State: READ |
 | |
 | Request Status Code Description New State |
 | |
 | READ 140 Modem error DISCONNECTED |
 | 161 6100 error DISCONNECTED |
 | 162 Timeout CONTROL |
 | 163 EOT received CONTROL |
 | 164 DLE EOT received DISCONNECTED |
 | 166 ENQ received CONTROL |
 | 172 Format error in CONTROL |
 | received data |
 | 173 Bad BCC or other CONTROL |
 | data error |
 | 177 Received block CONTROL |
 | too large |
 | 190 6100 error DISCONNECTED |
 | other READ |
 | WRITEREAD 0 Normal completion: WRITE if ACK; |
 | ACK or text READ if text |
 | 140 Modem error DISCONNECTED |
 | 161 6100 error DISCONNECTED |
 | 162 Timeout CONTROL |
 | 163 EOT received CONTROL |
 | 164 DLE EOT received DISCONNECTED |
 | 165 RVI received WRITE |
 | 166 ENQ received CONTROL |
 | 172 Format error in CONTROL |
 | received data |
 | 173 Bad BCC or other CONTROL if in |
 | error in data data |
 | sent or received received, |
 | WRITE if in |
 | data sent |
 | 175 Invalid acknowl. WRITE |
 | 177 Received block CONTROL |
 | too large |
 | 190 6100 error DISCONNECTED |
 | other READ |
 | CONTROL 0 Normal Completion DISCONNECTED |
 | (DISCONNECT) 140 Modem error DISCONNECTED |
 | 161 6100 error DISCONNECTED |
 | 162 Timeout DISCONNECTED |
 | 190 6100 error DISCONNECTED |
 | (WACK) 140 Modem error DISCONNECTED |
 | 161 6100 error DISCONNECTED |
 | 190 6100 error DISCONNECTED |
 | other READ |
 | |
 -----------------------------------------------------------------
 Figure 2-5. Status Codes to Leave READ State
 2-17