6100 BSC Programming Manual
 6100 BSC Link and Station Management
 MODEM SIGNALS AND THEIR USE
 6100 BSC uses the following modem signals:
 RS232
 Signal
 Mnemonic Function Pin
 AA Protective ground 1
 AB Signal reference (signal ground) 7
 BA Transmit data (TxD) 2
 BB Receive data (RxD) 3
 DB Transmit clock (TxC) 15
 DD Receive clock (RxC) 17
 DA Terminal-supplied transmit clock 24
 (TxC0)
 CA Request to send (RTS) 4
 CB Clear to send (CTS) 5
 CC Data set ready (DSR) 6
 CF Data carrier detect (DCD) 8
 CD Data terminal ready (DTR) 20
 The RS232 line interface module (LIM) also connects to the
 following signals, but BSC doesn't use them:
 Signal
 Mnemonic Function Value Pin
 SCF Secondary carrier detect Ignored* 12
 SBA Secondary data transmit Always 0 14
 SCA Secondary request to send Always OFF 19
 CE Ring indicator Ignored 22
 CH/CI Data rate select/indicator ON | Ignored** 23
 * Frequent transitions in this signal may cause a modem
 error. It is best to leave an open circuit.
 ** This signal is ON if connected by switch settings to the
 LIM driver; it is ignored if connected to the LIM receiver.
 The rest of this section describes how BSC uses the modem
 signals.