6100 MPS-B Programming Manual

WRITING APPLICATIONS THAT USE 6100 MPS-B
SET CONFIGURATION Request
Byte
Offset,Length
Parameter and Type Description_______________
MPSBHALF 17,1 BYTE 0 = half duplex
MPSBFULL 255 = full duplex
MPSBLEASED 18,1 BYTE 0 = leased line
MPSBSWITCHED 255 = switched line
MPSBCONTROLCF 19,1 BYTE 0 = control CF
MPSBNOCONTROLCF 255 = no control CF
MPSBNOAUTODISABLE 20,1 BYTE 0 = no auto disable
MPSBAUTODISABLE 255 = auto disable
MPSBNONSTOPOFF 21,1 BYTE 0 = no task/host
synchronization
MPSBNONSTOPON 255 = task/host
synchronization
Reserved 22,2 0
Reserved 24,2 0
The standard line configuration block can be initiated using
a SYSGEN.
3-43