WRITING APPLICATIONS THAT USE 6100 MPS-B
Enable Station Polling
The response buffer format is:
Function := 64
Status := 0 if the operation completed successfully, or
a code greater than zero if an error occurred
Request ID := The same as in the request
Text Out := 0
Text In := 0, or
Station count * 2 if status detail code present
in Text field
Text := Null, or
List composed of one 2-byte entry for each
station:
First byte = status detail code
Second byte = station index
3-49