INTRODUCTION TO 6100 MPS-B
Message Formats
FREE FORMAT SELECT REQUEST (ADM-2 protocol):
Select Specific Station Using MCW:
Text Out field = 2 + message length in bytes
Text field =
|<---- MCW ---->|<---------- message ---------->|
_______________________________/ /_____________
| | | | / / | |
| 0 | si | [STX] |<---- text --->| [ETX] |
| | | | / / | |
/ /
si = station-index from Poll/Select List
Select Specific Station Using sequence-header:
Text Out field = 7 + message length in bytes
Text field =
|<---- MCW ---->|<---------- sequence-header ---------->|
_________________________________________________________
| | | | | | | |
| 0 | 0 | [EOT] | a1 | a1 | q | [ENQ] | ...
| | | | | | | |_
|<---------- message ---------->|
_________________/ /_____________
| | / / | |
... | [STX] |<---- text --->| [ETX] |
| | / / | |
/ /
a1 = Station character address
q = Select function code
1-17