6100 MPS-B Programming Manual

6100 MPS-B LINK MANAGEMENT
POLL State
-----------------------------------------------------------------
| |
| Original State: POLL |
| |
| Request Status Code Description New State |
| |
| READ 0 Normal completion READ |
| 140 Modem error DISCONNECT |
| 161 6100 error DISCONNECT |
| 162 Timeout Unknown; use |
| Send EOT |
| 163 EOT received CONTROL |
| 172 Format error in CONTROL |
| received data |
| 173 Bad BCC or other Unknown; use |
| data error Send EOT |
| 177 Received text CONTROL |
| too large |
| 190 6100 error DISCONNECT |
| other DISCONNECT |
| |
| WRITEREAD 0 Normal completion: SELECT-TEXT |
| ACK or text if ACK; |
| READ if text |
| 140 Modem error DISCONNECT |
| 161 6100 error DISCONNECT |
| 162 Timeout Unknown; use |
| Send EOT |
| 163 EOT received CONTROL |
| 172 Format error in CONTROL |
| received data |
| 173 Bad BCC or other Unknown; use |
| error in data Send EOT |
| sent or received |
| 177 Received text CONTROL |
| too large |
| 190 6100 error DISCONNECT |
| other CONTROL |
| |
| CONTROL 0 Normal Completion DISCONNECT |
| (DISCONNECT) 140 Modem error DISCONNECT |
| 161 6100 error DISCONNECT |
| 162 Timeout DISCONNECT |
| 190 6100 error DISCONNECT |
| |
-----------------------------------------------------------------
Figure 2-4. Completion Codes to Leave POLL State
(Page 2 of 2)
2-11