Power-Failure Recovery
Power-Failure Recovery
NonStop S-series systems can stay operational for up to 30 seconds during a power
outage. This means that during any short power outage, the 6760 adapter remains
operational, while any modular disk and tape subsystems that were migrated from
NonStop K-series systems do not.
To avoid any possibility of a data integrity problem, any time that the system software
detects a power outage, the device state for the external disk drives and tape drives is
changed to DOWN. When power is normal again, the operator must restart these
devices to bring them back online using SCF commands.
For details on this topic, see Power-Failure Recovery on page 4-19.