6760 ServerNet/DA Manual
Installing and Moving the 6760 ServerNet/DA
6760 ServerNet/DA Manual—424879-003
2-13
View Configuration Information
Figure 2-5 shows how to install a 6760 adapter in an enclosure slot.
Continue with the following topic, View Configuration Information.
View Configuration Information
After a 6760 adapter is installed, you can view its configuration information and verify
that the adapter is available by issuing the SCF INFO ADAPTER command. For
example:
-> INFO ADAPTER $ZZSTO.#SNDA.GRP-1.MOD-1.SLOT-53, DETAIL
If everything appears normal in the report produced by the INFO command, continue
with Connect External Devices on page 2-14; otherwise, see the following topic, If the
Slot Was Previously Configured.
Figure 2-5. Installing a 6760 Adapter
CDT 008.CDD
1. Attach ESD grounding clip to
ventilation holes on PMF CRU or
IOMF CRU.
2. With ejector in full-open position,
align the lower edge of the adapter
with the slot. Then slide the adapter
into the slot.
3. Press lightly on the front of the
adapter so that the connector on the
adapter makes proper contact with
the backplane.