6763 Common Communication ServerNet Adapter Installation and Support Guide

Introduction
6763 Common Communication ServerNet Adapter Installation and Support Guide522309-005
1-11
SS7TE3 Ports and Cables
SS7TE3 Ports and Cables
Each SS7TE3 contains one 10/100 Ethernet port (RJ-45 connector) and two T1/E1/J1
ports (RJ-48C connectors). T1/E1/J1 ports (RJ-48C connectors) are not used for
SS7TE3 PICs. However, these ports are supported for SS7TE3 PICs. (To view PIC
part numbers, from the home page of NTL, select
Support and Service > Service Information > Part Numbers.)
Figure 1-5, Figure 1-6, and Figure 1-7 show the cabling options for SS7TE3s.
Note. The SCF labels that you must use to configure a CCSA are different than the labels
physically located on the CCSA. The SCF labels are 0 (zero) origin, with 1 corresponding to
the bottom most SAC proceeding upward. The physical CCSA labels are 1 origin, with 1
corresponding to the bottom most SAC proceeding upward.
Figure 1-5. Cabling a Model 6763-2 CCSA With Four SS7TE3 PICs
Figure 1-6. Cabling a Model 6763 CCSA With Two SS7TE3 PICs
PIC 1
PIC 0
6763-2 CCSA
RJ45 or
RJ-48C
To Customer Termination
Equipment
VST701.vsd
PIC 3
PIC 2
PIC 1
PIC 0
6763 CCSA
RJ45 or
RJ-48C
To Customer Termination
Equipment
Empty
Empty
VST704.vsd