6763 Common Communication ServerNet Adapter Installation and Support Guide
Installing a CCSA
6763 Common Communication ServerNet Adapter Installation and Support Guide—522309-005
2-5
Install a CCSA
Install a CCSA
Unpack and Inspect the CCSA
1. Put on an ESD wrist strap and attach the grounding clip to the antistatic mat.
2. Place the package containing the CCSA on the antistatic mat.
3. Open the packing container and remove the CCSA. Set aside the packing 
container in the event you need to return the CCSA. 
4. Visually inspect the CCSA and the backplane connector for damage. Use a 
flashlight, if necessary, to check for bent or broken pins. If the CCSA is damaged 
or has a damaged connector-pin socket, do not install it. Instead, contact your HP 
service provider.
Note. HP recommends that you install a CCSA first, then add the adapter using the 
Subsystem Control Facility (SCF). 
Table 2-2. Installation Checklist
Step Description
1. Unpack and Inspect the CCSA
.
2. Install a CCSA
.
3. Verify the Installation of the CCSA
.
4. Add and Start the CCSA Using SCF
.
Note. Whenever you handle a CCSA, follow standard operating practices to avoid damage to 
the equipment. See Review Standard Operating Practices
 on page 2-3.
Caution. When opening the packing container, be careful not to cut into the ESD protective 
bag.
Caution. If you insert a CCSA that has a damaged socket into a slot, that CCSA's backplane 
pins and the connectors on other adapter boards also inserted into that slot can be damaged.  
Moving a damaged adapter from slot to slot can damage other slots and other adapters. 