9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek 9710 for the Tandem Environment
Configuring the Compaq System for the 9710 Automated Cartridge Subsystem
6-21
• For a Cyclone system, to determine the I/O controller number:
♦ (I/O controller number) = %10* (segment address) +
(slot address)
Table 6-7 Subchannel Addresses for I/O Controllers
I/O Slot
Number
Subchannel
Address
I/O Slot
Number
Subchannel
Address
62 %040 (MFC only) 60 %240 (MFC only)
63 %030 61 %230
64 %020 62 %220
65 %120 63 %210
66 %130 64 %200
67 %140 (MFC only) 65 %300
66 %310
67 %320
68 %330
69 %340 (MFC only)
For Himalaya K10000, K20000, and Cyclone systems, the I/O
Subchannel address depends on the processor and the I/O channel
configuration. See Tandem’s NonStop Himalaya K10000/K20000
Planning and Configuration Guide or the NonStop Cyclone System
Configuration Guide for more information.
6.5.2 Memory Dump Considerations
How the system is configured affects what devices are used for a
memory dump. To use a T16/5155/5159 DLTtape Drive FRU to
capture memory dumps, read “Using a T16/5155/5159 DLTtape
Drive FRU drive for a Memory Dump”.