9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek 9710 for the Tandem Environment 
Configuring the Compaq System for the 9710 Automated Cartridge Subsystem  
6-25
3216 Controller 
1. Specify the name of the controller. 
2. Specify 3216 as the controller product code. 
3. Specify the processors and, if applicable, the channel numbers 
attached to the controller. 
4. Determine the subchannel address required for each 3216 
controller. (Use Table 6-6) 
Example for the Himalaya K100, K200, K1000, K2000, and CLX 
systems: 
!Controller/ 
!CIU name 
Product Number  Processor Numbers  Subchannel Address 
!       
TAPEA  3216  0,1  %030; !slot 63 
Example for the Himalaya K10000 and K20000 systems: 
!Controller/ 
!CIU name 
Product Code  Processors/ 
Channels 
Subchannel 
Address 
!       
TAPEA  3216  0.0, 1.0  %200; !slot 64 
Example for Cyclone systems: 
!Controller/ 
!CIU name 
Product Code  Processors/ 
Channels 
Subchannel 
Address 
!       
TAPEB  3216  0.0, 1.0  %030; 
6.5.6  Modifying the PERIPHERALS Paragraph 
In the PERIPHERALS paragraph of the CONFTEXT configuration 
file, specify the logical name of the tape drive, the name of the tape 
controller with tape unit number and the macro 5190 (specify 5190 
for the T16/5155/5159 DLTtape Drive FRU drive). 