9710 (StorageTek) Addendum for NonStop Servers

Addendum to the StorageTek 9710 for the Tandem Environment
Configuring the Compaq System for the 9710 Automated Cartridge Subsystem
6-25
3216 Controller
1. Specify the name of the controller.
2. Specify 3216 as the controller product code.
3. Specify the processors and, if applicable, the channel numbers
attached to the controller.
4. Determine the subchannel address required for each 3216
controller. (Use Table 6-6)
Example for the Himalaya K100, K200, K1000, K2000, and CLX
systems:
!Controller/
!CIU name
Product Number Processor Numbers Subchannel Address
!
TAPEA 3216 0,1 %030; !slot 63
Example for the Himalaya K10000 and K20000 systems:
!Controller/
!CIU name
Product Code Processors/
Channels
Subchannel
Address
!
TAPEA 3216 0.0, 1.0 %200; !slot 64
Example for Cyclone systems:
!Controller/
!CIU name
Product Code Processors/
Channels
Subchannel
Address
!
TAPEB 3216 0.0, 1.0 %030;
6.5.6 Modifying the PERIPHERALS Paragraph
In the PERIPHERALS paragraph of the CONFTEXT configuration
file, specify the logical name of the tape drive, the name of the tape
controller with tape unit number and the macro 5190 (specify 5190
for the T16/5155/5159 DLTtape Drive FRU drive).