9710 (StorageTek) Addendum for NonStop Servers
Addendum to the StorageTek 9710 for the Tandem Environment 
Configuring the Compaq System for the 9710 Automated Cartridge Subsystem  
6-26
Use the following steps to add an entry to the PERIPHERALS  
paragraph of the configuration file. For more information about 
specifying PERIPHERALS paragraph entries for tape devices, see 
the System Generation Manual for Disk and Tape Devices. 
1. Specify the logical device name of the tape drive. (The 
examples use $BACKUP and $DUMP.) 
2. Specify the name of the controller for each drive. Use the 
controller name specified in the CONTROLLERS paragraph. 
(Either the MFC logical tape controller or the 3216 name. The 
examples use TAPEA.) 
3. Append the unit number to the controller name. A 
T16/5155/5159 DLTtape Drive FRU drive attached to an 
MFC always uses unit number 5. The 3216 controller can 
support two tape drives with the unit numbers 4 and 5. The 
SCSI ID configured during installation using operator buttons 
on the front panel of the drive FRU must match the unit 
number. For more information on the SCSI ID, see “Checking 
and Setting the SCSI ID”. 
4. Specify 5190 as the macro name. (The T16/5155/5159 
DLTtape Drive FRU drive(s) use the same macro.) 
5. Specify the compression modifier following the macro name. 
This modifier is valid only for the 5190/5150/5151/5155/5159 
tape drives. The modifier enables or disables compression mode 
for the 5150/5151/5155/5159 tape drive: 
Modifier  5155/5159 Tape Drive Action 
NOCOMPRESSION  Data is written without compression 
COMPRESSION  Data is written using compression 