9710 (StorageTek) Addendum for NonStop Servers
Addendum tot he StorageTek 9710 for the Tandem Environment
Configuring the 5155/5159 Digital Linear Tape FRU for the Himalaya S series Servers  
7 4
 Configuration Guidelines
The s
DLTtape
5155/5159 for use on the system: 
If installing the 5155/5159  
as...  
Then . . . 
The only tape drive on the bus  
Be sure to use a SCSI ID 5 for the 
tape drive. The SCSI ServerNet 
addressable controller (SAC) 
supports copper cables only 
(G06.XX and earlier). 
Terminate the bus by installing a 
terminator on the last SCSI device. 
Note: When there is more than one drive on the bus, each drive 
must have a different SCSI ID setting. 
7.4.2  Changing the SCSI ID 
To change the SCSI ID locate the push-button switch on the rear of 
the drive. Press the switch button(s) above or below the number 
display (0-7) to set the desired SCSI ID. Press the top button to 
increase the number or press the bottom button to decrease the 
number. The best tool to use is a bent paper clip. 
Caution  
 Never use a pencil to set the ID switch on the 5155/5159. 
 The lead will break off while trying to set the ID. 
7.5  Connect the Cables 
Section 2.5 describes the physical connections of the 5155/5159,  
including the Rear Panel layout, SCSI cable connections, SCSI bus 
termination and Power connections.   