9710 (StorageTek) Addendum for NonStop Servers

Addendum tot he StorageTek 9710 for the Tandem Environment
Configuring the 5155/5159 Digital Linear Tape FRU for the Himalaya S-series Servers
7-12
Group and slot labels help locate FRUs that need service. Some
software might show the location of a FRU using abbreviations for
group, module, and slot. For example the Subsystem Control
Facility (SCF) storage subsystem might display the location of a
PMF CRU as:
PMF.GRP-1.MOD-1.SLOT-50
For more information on system organization, group numbering, or
labeling in a Himalaya S-series server, refer to the Himalaya S-
series Planning and Configuration Guide.
7.8 Completing the PMF CRU Configuration Form
To connect a tape drive FRU to a PMF CRU, document the
configuration of the PMF CRU using a PMF CRU Configuration
Form. This form documents configurable entities associated with
the connectors on a PMF CRU. It also provides information about
the tape drive to be connected to the PMF CRU.
Note: The SCSI passthrough terminator is preinstalled on the
differential SCSI port.
Figure 7-9 shows an example of a completed PMF CRU
Configuration Form. For a blank PMF FRU Configuration, refer to
the Himalaya S-series Planning and Configuration Guide.
Complete the SCSI Port information block on the form if attaching a
tape drive to a PMF CRU:
Enter the product number of the tape drive in the Product Number
field. The correct product number is 5190.
Enter the Subsystem Control Facility (SCF) name of the tape drive
in the SCF Name field.