9710 (StorageTek) Addendum for NonStop Servers
Addendum tot he StorageTek 9710 for the Tandem Environment
Configuring the 5155/5159 Digital Linear Tape FRU for the Himalaya S-series Servers
7-20
Use the INFO command to verify that the tape drive has been
removed from the system:
->INFO $TAPE*
For more information on the STATUS, DELETE, and INFO
commands, see the SCF Reference Manual for the Storage
Subsystem.
7.10 Terminate the SCSI Bus
Note: The SCSI bus must be terminated at the last SCSI device.
Table 7-2 tells when and where to add a terminator to the SCSI bus.
If the 5155.5159 is … Then…
The last or only tape drive on the bus, to
Terminate.
1. Connect the SCSI terminator to one
of the SCSI signal connectors on the
9710 ACS Patch Panel.
2. Snap the wire cable clamps into
place to secure the terminator.
Not the last or only tape drive on the
SCSI bus.
3. Be sure to install the terminator at
the end of the bus or on the second
tape drive.
7.11 Connect the Power Cord
To connect the power cord:
1. Be sure the 5155/5159 Tape Subsystem power switch is set to 0 (Off).